Date of Award:
5-1987
Document Type:
Thesis
Degree Name:
Master of Science (MS)
Department:
Animal, Dairy, and Veterinary Sciences
Committee Chair(s)
David H. Clark
Committee
David H. Clark
Committee
Robert Lamb
Committee
Wade Dewey
Abstract
One hundred wheat samples, with moisture ranging from 14.42 %to 7.66 %, were used to test the moisture loss from grinding, the accuracy of moisture content from two different electric moisture meters, and the accuracy and precision of Near Infrared Reflectance Spectroscopy whole wheat moisture determination.
Fifty samples were ground through three grinders, Wiley, Cemotec, and UDY Cyclone grinder. Moisture content was determined from these ground samples, and compared with whole wheat moisture. The Cemotec grinder caused the least amount of moisture loss, followed by Wiley and then UDY Cyclone.
Fifty whole wheat samples were used to calibrate the Tecator GP6010 moisture meter. Another 50 whole wheat samples with known moisture values, were used to test the accuracy of the Tecator GP6010 moisture meter. Moisture and compared to moisture readings from a Motomco meter. Tecator moisture value had a better correlation coefficient to whole wheat moisture than Motomco moisture values (0.935 and 0.917, respectively). Three sample sets from different grinding preparation methods were scanned by NIRS. Eight moisture values were entered into the computer, and separate multiple regression equations developed.
Sixteen wheat samples with known moisture content were used to test the equations. For whole wheat moisture equation, SEA and r 2 were 0.159 and 0.991, 0.223 and 0.972, 0 .223 and 0 .973, 0.322 and 0.888, 0.218 and 0.968, 0.248 and 0.969, 0.208 and 0.978, 0.249 and 0.970 for whole wheat, Cemotec, Wiley, UDY, C3, C5, C6, and Motomco moisture, respectively. For Cemotec moisture equation, SEA and r2 were 0.226 and 0.944, 0.208 and 0.927, 2.267 and 0.071, 0.208 and 0.853, 0.272 and 0.876, 2.296 and 0.088, 0.291 and 0.896, 0.248 and 0.927, for whole wheat, Cemotec, Wiley, Udy, C3, CS, C6, and Motomco moisture, respectively. For UDY moisture equation, SEA and r2 were 0 .402 and 0.909, 0.364 and 0.900, 0.353 and 0.907, 0.119 and 0 .973, 0.407 and 0.858, 0.484 and 0.856, 0.514 and 0.835, 0.403 and 0.897, for whole wheat, Cemotec, Wiley, UDY, Tecator C3, CS, C6, and Motomco moisture, respectively. Many desirable features make the whole wheat method a good direction for Near Infrared Reflectance Spectroscopy.
Checksum
bc4365113aa4d484970633e2af7f8e8a
Recommended Citation
Chang, Weider, "Comparing Different Methods for Determining Moisture in Wheat Using NESR Infrared Reflectance Spectroscopy" (1987). All Graduate Theses and Dissertations, Spring 1920 to Summer 2023. 4068.
https://digitalcommons.usu.edu/etd/4068
Included in
Copyright for this work is retained by the student. If you have any questions regarding the inclusion of this work in the Digital Commons, please email us at .