Comparison of Single-Point and Continuous Sampling Methods for Estimating Residential Indoor Temperature and Humidity
Document Type
Article
Journal/Book Title/Conference
Journal of Occupational and Environmental Hygiene
Volume
12
Issue
11
Publisher
Taylor & Francis
Publication Date
1-1-2015
First Page
785
Last Page
794
Abstract
Residential temperature and humidity are associated with multiple health effects. Studies commonly use single-point measures to estimate indoor temperature and humidity exposures, but there is little evidence to support this sampling strategy. This study evaluated the relationship between single-point and continuous monitoring of air temperature, apparent temperature, relative humidity, and absolute humidity over four exposure intervals (5-min, 30-min, 24-hr, and 12-days) in 9 northern Utah homes, from March-June 2012. Three homes were sampled twice, for a total of 12 observation periods. Continuous data-logged sampling was conducted in homes for 2–3 wks, and simultaneous single-point measures (n = 114) were collected using handheld thermo-hygrometers. Time-centered single-point measures were moderately correlated with short-term (30-min) data logger mean air temperature (r = 0.76, β = 0.74), apparent temperature (r = 0.79, β = 0.79), relative humidity (r = 0.70, β = 0.63), and absolute humidity (r = 0.80, β = 0.80). Data logger 12-day means were also moderately correlated with single-point air temperature (r = 0.64, β = 0.43) and apparent temperature (r = 0.64, β = 0.44), but were weakly correlated with single-point relative humidity (r = 0.53, β = 0.35) and absolute humidity (r = 0.52, β = 0.39). Of the single-point RH measures, 59 (51.8%) deviated more than ±5%, 21 (18.4%) deviated more than ±10%, and 6 (5.3%) deviated more than ±15% from data logger 12-day means. Where continuous indoor monitoring is not feasible, single-point sampling strategies should include multiple measures collected at prescribed time points based on local conditions.
Recommended Citation
Johnston JD, Magnusson BM, Eggett D, Collingwood SC, and Bernhardt SA. 2015. Comparison of single-point measurements and continuous sampling methods for estimating residential indoor air temperature and relative humidity in arid climates. J Occup Environ Hyg. DOI: 10.1080/15459624.2015.1047024.