The Effects of Hydraulic Jump Location on Air Entrainment in Closed Conduits
Document Type
Article
Journal/Book Title/Conference
Journal of Hydraulic Research
Volume
50
Issue
3
Publication Date
7-1-2012
First Page
298
Last Page
303
Abstract
In vented closed conduit conveyance systems, air entrained through hydraulic jumps can be problematic for system operation. While various factors influencing air entrainment have been reported in the literature, no specific attention has been paid to the hydraulic jump location relative to the point of downstream air release. To better understand the effects of jump location on air entrainment, in this study, experiments were conducted in a vented, circular conduit with variable hydraulic jump locations relative to the pipe outlet. When the hydraulic jump was fully contained within the pipe, the air entrainment rate was dependent on the Froude number immediately upstream of the jump but was independent of the jump location within the pipe. The rate of air entrainment significantly increased, however, when the hydraulic jump was not fully contained within the pipe. For this condition, the distance from the toe of the jump to the pipe outlet significantly influences the air entrainment rate.
Recommended Citation
Jul 2012: The effects of Hydraulic Jump Location on Air Entrainment in Closed Conduits. Journal of Hydraulic Research (Josh D. Mortenson, * Blake P. Tullis) Volume 50, No. 3 (2012), pp. 298-303