Document Type
Presentation
Publication Date
1986
Abstract
A methodology is described for efficiently evaluating possible injection/extraction pumping schemes to most economically contain a groundwater contaminant plume. A multi-objective model is analyzed with a micro-computer. Simulation and optimization is performed by employing the response matrix method.
Recommended Citation
Peralta, R.C. and R.Ward. 1986. Optimal piezometric surface management for groundwater contaminant control. Paper # 86‑2513, American Society of Agricultural Engineers. Presented by Ward at ASAE winter meeting, Chicago, Illinois, Dec 18. 14 p.