Abstract
A crossover design study was conducted to determine if reducing pain, by using alternative sites off the finger tip, would increase testing frequency and improve clinical outcome as measured by glycosylated hemoglobin. Subjects with type 1 and type 2 diabetes tested with the FreeStyle alternative-site meter (group 1) or tested with their original meter (group 2). After 3 months the subjects used the alternate meter. Testing frequency and blood glucose concentrations were recorded for the month before the study began and monthly thereafter. Glycosylated hemoglobin was tested initially, at the crossover point, and at study conclusion. Insulin users increased testing frequency from 2.4 to 3.0 tests per day. Testing frequency for non-insulin users remained the same at 1.5 tests per day. Testing frequency was essentially the same with the FreeStyle and the original meters. The average hemoglobin A1c was 7.4% (standard deviation 1.5%) initially, 7.3% (standard deviation 1.5%) at the crossover point, and 6.9% (standard deviation 1.1%) after 6 months. There was no significant difference in hemoglobin A1c measurements between meter types after 6 months. Thirteen months later a final hemoglobin A1c, testing frequency, and a questionnaire regarding meter preference and pain rating were obtained. Seventy-four percent of participants preferred the alternative-site meter, which was rated as significantly (p < .05) less painful. Testing frequency significantly improved (p = .001) while free strips were being provided. Testing frequency 13 months later was not significantly different from the baseline (p = .101). Hemoglobin A1c was significantly lower 6 months after the study began (p = .000) and 13 months later (p = .008) at baseline.
Checksum
5dbf9ea5ad05b006e4a503ffdb0fcda4
Recommended Citation
Bennion, Nancy, "The Effects of Alternative-Site Blood Glucose Monitoring on Testing Frequency, Pain Rating, and Glycosylated Hemoglobin" (2003). All Graduate Theses and Dissertations, Spring 1920 to Summer 2023. 5495.
https://digitalcommons.usu.edu/etd/5495
Included in
Copyright for this work is retained by the student. If you have any questions regarding the inclusion of this work in the Digital Commons, please email us at .